Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 136
Filtrar
2.
Radiol Phys Technol ; 17(1): 24-46, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38319563

RESUMO

This review focuses on positron emission tomography (PET) imaging algorithms and traces the evolution of PET image reconstruction methods. First, we provide an overview of conventional PET image reconstruction methods from filtered backprojection through to recent iterative PET image reconstruction algorithms, and then review deep learning methods for PET data up to the latest innovations within three main categories. The first category involves post-processing methods for PET image denoising. The second category comprises direct image reconstruction methods that learn mappings from sinograms to the reconstructed images in an end-to-end manner. The third category comprises iterative reconstruction methods that combine conventional iterative image reconstruction with neural-network enhancement. We discuss future perspectives on PET imaging and deep learning technology.


Assuntos
Aprendizado Profundo , Processamento de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Redes Neurais de Computação , Algoritmos , Imagens de Fantasmas
4.
Magn Reson Med Sci ; 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38346767

RESUMO

PURPOSE: The purpose of this study was to do a feasibility study on a microstrip transmission line (MS) RF coil for a positron emission tomography (PET) insert in a 7 Tesla human MRI system. The proposed MS coil integrated the RF shield of the PET detector as the ground conductor of the coil. We called the integrated module "MS PET coil." METHODS: A single-channel MS PET coil was developed with an integrated RF-shielded PET detector module. For comparison, we also studied a conventional MS coil with a single-layer ground conductor. A lutetium fine silicate (LFS) scintillation crystal block (14 × 14 × 4-layer) with a silicon photomultiplier (Hamamatsu Photonics K.K., Shizuoka, Japan) and a front-end readout circuit board were mounted inside the shield cage of the MS PET coil. The MS PET coil was studied with and without PET detectors. All three coil configurations were studied with a homogeneous phantom in a 7T MRI system (Siemens Healthineers, Erlangen, Germany). PET data measurements were conducted using a Cesium-137 radiation point source. RESULTS: The MR images were similar for the MS coil and the empty MS PET coil, as well as for the cases of MS PET coil with and without PET measurements. Compared to the empty MS PET coil (without PET detector and cable RF shield), decreases in SNR, increases in image noise and RF power, and a slight decrease in resonance frequency were seen for the case of the MS PET coil with the detector and cable shield. Differences in the PET energy histograms or in the crystal identification maps with and without MRI measurements were negligible. CONCLUSIONS: Both the MRI and PET performances of the MS PET coil showed responses that matched the MS coil responses. The performance variations of MRI data with and without PET measurement and PET data with and without MR imaging were negligible.

5.
Sci Rep ; 14(1): 2601, 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38297114

RESUMO

This work provides the first experimental proof of an increased neutron capture photon signal following the introduction of boron to a PMMA phantom during helium and carbon ion therapies in Neutron Capture Enhanced Particle Therapy (NCEPT). NCEPT leverages [Formula: see text]B neutron capture, leading to the emission of detectable 478 keV photons. Experiments were performed at the Heavy Ion Medical Accelerator in Chiba, Japan, with two Poly(methyl methacrylate) (PMMA) targets, one bearing a boron insert. The BeNEdiCTE gamma-ray detector measured an increase in the 478 keV signal of 45 ± 7% and 26 ± 2% for carbon and helium ion irradiation, respectively. Our Geant4 Monte Carlo simulation model, developed to investigate photon origins, found less than 30% of detected photons originated from the insert, while boron in the detector's circuit boards contributed over 65%. Further, the model investigated detector sensitivity, establishing its capability to record a 10% increase in 478 keV photon detection at a target [Formula: see text]B concentration of 500 ppm using spectral windowing alone, and 25% when combined with temporal windowing. The linear response extended to concentrations up to 20,000 ppm. The increase in the signal in all evaluated cases confirm the potential of the proposed detector design for neutron capture quantification in NCEPT.

6.
Radiat Prot Dosimetry ; 200(2): 130-142, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-37961917

RESUMO

Previously, we have developed DynamicMC for modeling relative movement of Oak Ridge National Laboratory phantom in a radiation field for the Monte Carlo N-Particle package (Health Physics. 2023,124(4):301-309). Using this software, three-dimensional dose distributions in a phantom irradiated by a certain mono-energetic (Mono E) source can be deduced through its graphical user interface. In this study, we extended DynamicMC to be used in combination with the Particle and Heavy Ion Transport code System (PHITS) by providing it with a higher flexibility for dynamic movement for an anthropomorphic phantom. For this purpose, we implemented four new functions into the software, which are (1) to generate not only Mono E sources but also those having an energy spectrum of an arbitrary radioisotope (2) to calculate the absorbed doses for several radiologically important organs (3) to automatically average the calculated absorbed doses along the path of the phantom and (4) to generate user-defined slab shielding materials. The first and third items utilize the PHITS-specific modalities named radioisotope-source and sumtally functions, respectively. The computational cost and complexity can be dramatically reduced with these features. We anticipate that the present work and the developed open-source tools will be in the interest of nuclear radiation physics community for research and teaching purposes.


Assuntos
Física Médica , Radiometria , Radiometria/métodos , Física Médica/métodos , Software , Movimento , Imagens de Fantasmas , Radioisótopos , Método de Monte Carlo
7.
Radiol Phys Technol ; 17(1): 60-70, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37874462

RESUMO

The purpose of this study is to evaluate the RF field responses of partial-ring RF-shielded oval-shaped positron emission tomography (PET) inserts that are used in combination with an MRI body RF coil. Partial-ring PET insert is particularly suitable for interventional investigation (e.g., trimodal PET/MRI/ultrasound imaging) and intraoperative (e.g., robotic surgery) PET/MRI studies. In this study, we used electrically floating Faraday RF shield cages to construct different partial-ring configurations of oval and cylindrical PET inserts and performed experiments on the RF field, spin echo and gradient echo images for a homogeneous phantom in a 3 T clinical MRI system. For each geometry, partial-ring configurations were studied by removing an opposing pair or a single shield cage from different positions of the PET ring. Compared to the MRI-only case, reduction in mean RF homogeneity, flip angle, and SNR for the detector opening in the first and third quadrants was approximately 13%, 15%, and 43%, respectively, whereas the values were 8%, 23%, and 48%, respectively, for the detector openings in the second and fourth quadrants. The RF field distribution also varied for different partial-ring configurations. It can be concluded that the field penetration was high for the detector openings in the first and third quadrants of both the inserts.


Assuntos
Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Desenho de Equipamento , Tomografia por Emissão de Pósitrons/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Ondas de Rádio
8.
Jpn J Radiol ; 42(4): 382-390, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38110835

RESUMO

PURPOSE: To perform an MRI compatibility study of an RF field-penetrable oval-shaped PET insert that implements an MRI built-in body RF coil both as a transmitter and a receiver. METHODS: Twelve electrically floating RF shielded PET detector modules were used to construct the prototype oval PET insert with a major axis of 440 mm, a minor axis of 350 mm, and an axial length of 225 mm. The electric floating of the PET detector modules was accomplished by isolating the cable shield from the detector shield using plastic tape. Studies were conducted on the transmit (B1) RF field, the image signal-to-noise ratio (SNR), and the RF pulse amplitude for a homogeneous cylindrical (diameter: 160 mm and length: 260 mm) phantom (NaCl + NiSO4 solution) in a 3 T clinical MRI system (Verio, Siemens, Erlangen, Germany). RESULTS: The B1 maps for the oval insert were similar to the MRI-only field responses. Compared to the MRI-only values, SNR reductions of 51%, 45%, and 59% were seen, respectively, for the spin echo (SE), gradient echo (GE), and echo planar (EPI) images for the case of oval PET insert. Moreover, the required RF pulse amplitudes for the SE, GE, and EPI sequences were, respectively, 1.93, 1.85, and 1.36 times larger. However, a 30% reduction in the average RF reception sensitivity was observed for the oval insert. CONCLUSIONS: The prototype floating PET insert was a safety concern for the clinical MRI system, and this compatibility study provided clearance for developing a large body size floating PET insert for the existing MRI system. Because of the RF shield of the insert, relatively large RF powers compared to the MRI-only case were required. Because of this and also due to low RF sensitivity of the body coil, the SNRs reduced largely.


Assuntos
Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Humanos , Tomografia por Emissão de Pósitrons/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Ondas de Rádio , Razão Sinal-Ruído
9.
Radiol Phys Technol ; 16(4): 516-531, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37782423

RESUMO

Inter-crystal scattering (ICS) events cause degradation of the contrast in PET images. We developed the X'tal cube PET detector with submillimeter spatial resolution, which consisted of a segmented LYSO scintillator and 96 MPPCs. For this high spatial resolution PET detector, the ICS event was not negligible. In this study, we proposed a method to discriminate the ICS events and showed its feasibility by the following method. For each 96 MPPC, we measured the mean and standard deviation of the peak in the pulse height distribution obtained by the photoabsorption events in a scintillator pixel. Every time a newly detected event was identified as the segment, we monitored the reduced chi-square value that was calculated with the pulse height and the prepared mean and the standard deviation for each 96 MPPC. Since the pulse height caused by the photoabsorption event resulted in a small reduced chi-square value, we could eliminate the ICS events by setting a threshold on the reduced chi-square value. We carried out both a Monte Carlo simulation and a scanning experiment. By the simulation, we confirmed that the threshold of the reduced chi square significantly discriminated the ICS event. We obtained the response function by a scanning experiment with a 0.2 mm slit beam of 511 keV gamma-ray. The standard deviation of the response function was improved from 1.6 to 1.06 mm by eliminating the ICS events. The proposed method could significantly eliminate the ICS events and retain the true events.


Assuntos
Fótons , Tomografia por Emissão de Pósitrons , Tomografia por Emissão de Pósitrons/métodos , Simulação por Computador , Método de Monte Carlo , Raios gama
10.
Radiol Phys Technol ; 16(4): 552-559, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37819445

RESUMO

Attenuation correction (AC) is essential for quantitative positron emission tomography (PET) images. Attenuation coefficient maps (µ-maps) are usually generated from computed tomography (CT) images when PET-CT combined systems are used. If CT has been performed prior to PET imaging, pre-acquired CT can be used for brain PET AC, because the human head is almost rigid. This pre-acquired CT-based AC approach is suitable for stand-alone brain-dedicated PET, such as VRAIN (ATOX Co. Ltd., Tokyo, Japan). However, the headrest of PET is different from the headrest in pre-acquired CT images, which may degrade the PET image quality. In this study, we prepared three different types of µ-maps: (1) based on the pre-acquired CT, where namely the headrest is different from the PET system (µ-map-diffHr); (2) manually removing the headrest from the pre-acquired CT (µ-map-noHr); and (3) artificially replacing the headrest region with the headrest of the PET system (µ-map-sameHr). Phantom images by VRAIN using each µ-map were investigated for uniformity, noise, and quantitative accuracy. Consequently, only the uniformity of the images using µ-map-diffHr was out of the acceptance criteria. We then proposed an automated method for removing the headrest from pre-acquired CT images. In comparisons of standardized uptake values in nine major brain regions from the 18F-fluoro-2-deoxy-D-glucose-PET of 10 healthy volunteers, no significant differences were found between the µ-map-noHr and the µ-map-sameHr. In conclusion, pre-acquired CT-based AC with automated headrest removal is useful for brain-dedicated PET such as VRAIN.


Assuntos
Encéfalo , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Encéfalo/diagnóstico por imagem , Cabeça/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Tomografia por Emissão de Pósitrons/métodos , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos
11.
Life (Basel) ; 13(8)2023 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-37629558

RESUMO

Positron emission tomography (PET) is an imaging modality used for the noninvasive assessment of tumor staging and response to therapy. PET with 18F labeled fluorodeoxyglucose (18F-FDG PET) is widely used to assess the active and inactive lesions in patients with multiple myeloma (MM). Despite the availability of 18F-FDG PET for the management of MM, PET imaging is less sensitive than next-generation flow cytometry and sequencing. Therefore, the novel PET radiotracers 64Cu-LLP2A, 68Ga-pentixafor, and 89Zr-daratumumab have been developed to target the cell surface antigens of MM cells. Furthermore, recent studies attempted to visualize the tumor-infiltrating lymphocytes using PET imaging in patients with cancer to investigate their prognostic effect; however, these studies have not yet been performed in MM patients. This review summarizes the recent studies on PET with 18F-FDG and novel radiotracers for the detection of MM and the resulting preclinical research using MM mouse models and clinical studies. Novel PET technologies may be useful for developing therapeutic strategies for MM in the future.

12.
Phys Med Biol ; 68(19)2023 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-37625420

RESUMO

Objective.Tumour response to radiation therapy appears as changes in tumour vascular condition. There are several methods for analysing tumour blood circulatory changes one of which is dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), but there is no method that can observe the tumour vascular condition and physiological changes at the site of radiation therapy. Positron emission tomography (PET) has been applied for treatment verification in charged particle therapy, which is based on the detection of positron emitters produced through nuclear fragmentation reactions in a patient's body. However, the produced positron emitters are washed out biologically depending on the tumour vascular condition. This means that measuring the biological washout rate may allow evaluation of the tumour radiation response, in a similar manner to DCE-MRI. Therefore, this study compared the washout rates in rats between in-beam PET during12C ion beam irradiation and DCE-MRI.Approach.Different vascular conditions of the tumour model were prepared for six nude rats. The tumour of each nude rat was irradiated by a12C ion beam with simultaneous in-beam PET measurement. In 10-12 h, the DCE-MRI experiment was performed for the same six nude rats. The biological washout rate of the produced positron emitters (k2,1st) and the MRI contrast agent (k2a) were derived using the single tissue compartment model.Main results.A linear correlation was observed betweenk2,1standk2a, and they were inversely related to fractional necrotic volume.Significance.This is the first animal study which confirmed the biological washout rate of in-beam PET correlates closely with tumour vascular condition measured with the MRI contrast agent administrated intravenously.


Assuntos
Meios de Contraste , Tomografia Computadorizada por Raios X , Animais , Ratos , Ratos Nus , Tomografia por Emissão de Pósitrons , Imageamento por Ressonância Magnética , Carbono
13.
Biomed Phys Eng Express ; 9(5)2023 08 29.
Artigo em Inglês | MEDLINE | ID: mdl-37586333

RESUMO

Objective. A crosshair light sharing (CLS) PET detector as a TOF-DOI PET detector with high spatial resolution has been developed. To extend that work, a detector calibration method was developed to achieve both higher coincidence resolving time (CRT) and DOI resolution.Approach. The CLS PET detector uses a three-layer reflective material in a two-dimensional crystal array to form a loop structure within a pair of crystals, enabling a CRT of about 300 ps and acquisition of DOI from multi-pixel photon counter (MPPC) output ratios. The crystals were 1.45 × 1.45 × 15 mm3fast LGSO, and the crystal array was optically coupled to an MPPC array. It is important to reduce as many inter-crystal scattering (ICS) events as possible in advance for the accurate detector calibration. DOI information is also expected to improve the CRT because it can estimate the time delay due to the detection depth of crystals.Main results. Using crystal identification and light collection rate of the highest MPPC output reduces the number of ICS events, and CRT is improved by 26%. In addition, CRT is further improved by 13% with a linear correction of time delay as a function of energy. The DOI is ideally estimated from the output ratio of only the MPPC pairs optically coupled to the interacted crystals, which is highly accurate, but the error is large due to light leakage in actual use. The previous method, which also utilizes light leakage to calculate the output ratio, is less accurate, but the error can be reduced. Using the average of the two methods, it is possible to improve the DOI resolution by 12% while maintaining the smaller error.Significance. By applying the developed calibration method, the CLS PET detector achieves the CRT of 251 ps and the DOI resolution of 3.3 mm.


Assuntos
Fótons , Tomografia por Emissão de Pósitrons , Calibragem , Tomografia por Emissão de Pósitrons/métodos
15.
Phys Med Biol ; 68(15)2023 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-37406637

RESUMO

Objective. Deep image prior (DIP) has recently attracted attention owing to its unsupervised positron emission tomography (PET) image reconstruction method, which does not require any prior training dataset. In this paper, we present the first attempt to implement an end-to-end DIP-based fully 3D PET image reconstruction method that incorporates a forward-projection model into a loss function.Approach. A practical implementation of a fully 3D PET image reconstruction could not be performed at present because of a graphics processing unit memory limitation. Consequently, we modify the DIP optimization to a block iteration and sequential learning of an ordered sequence of block sinograms. Furthermore, the relative difference penalty (RDP) term is added to the loss function to enhance the quantitative accuracy of the PET image.Main results. We evaluated our proposed method using Monte Carlo simulation with [18F]FDG PET data of a human brain and a preclinical study on monkey-brain [18F]FDG PET data. The proposed method was compared with the maximum-likelihood expectation maximization (EM), maximuma posterioriEM with RDP, and hybrid DIP-based PET reconstruction methods. The simulation results showed that, compared with other algorithms, the proposed method improved the PET image quality by reducing statistical noise and better preserved the contrast of brain structures and inserted tumors. In the preclinical experiment, finer structures and better contrast recovery were obtained with the proposed method.Significance.The results indicated that the proposed method could produce high-quality images without a prior training dataset. Thus, the proposed method could be a key enabling technology for the straightforward and practical implementation of end-to-end DIP-based fully 3D PET image reconstruction.


Assuntos
Fluordesoxiglucose F18 , Processamento de Imagem Assistida por Computador , Humanos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Tomografia por Emissão de Pósitrons/métodos , Algoritmos , Imagens de Fantasmas
16.
Radiol Phys Technol ; 16(2): 254-261, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36943646

RESUMO

In Compton PET, that has a scatterer inserted inside a PET ring, there are multi-interaction events that can be treated as both PET and Compton events. A PET event from multi-interaction events that include a Compton event and a photoelectric absorption event or two Compton events can be extracted by applying a PET recovery method. In this study, we aimed to establish a method to maximize image quality by utilizing such redundant events. We conducted brain-scale Monte Carlo simulations of a C-shaped Compton-PET geometry and a whole gamma imaging (WGI) geometry. Images were reconstructed by a hybrid image reconstruction method combining both PET and Compton events. The result showed that the spatial resolution was improved when treated as PET events while keeping the noise level. The effect of improvement was more significant in WGI than in C-shaped Compton PET because the number of events recovered as PET events having more accurate spatial information was much larger in WGI. When the PET-recovered multi-interaction events were also included as Compton events in the hybrid reconstruction, we did not observe any improvement in image quality, while the number of used events was largest. The results suggested that treating events as PET events exclusively was better for image quality.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons , Processamento de Imagem Assistida por Computador/métodos , Método de Monte Carlo , Raios gama , Tomografia por Emissão de Pósitrons/métodos , Imagens de Fantasmas , Algoritmos
17.
Health Phys ; 124(4): 301-309, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36728190

RESUMO

ABSTRACT: The present work introduces an open-source graphical user interface (GUI) computer program called DynamicMC. The present program has the ability to generate ORNL phantom input script for the Monte Carlo N-Particle (MCNP) package. The relative dynamic movement of the radiation source with respect to the ORNL phantom can be modeled, which essentially resembles the dynamic movement of source-to-target (i.e., human phantom) distance in a 3-dimensional radiation field. The present program makes the organ-based dosimetry of the human body much easier, as users are not required to write lengthy scripts or deal with any programming that many may find tedious, time consuming, and error prone. In this paper, we have demonstrated that the present program can successfully model simple and complex relative dynamic movements (i.e., those involving rotation of source and human phantom in a 3-dimensional field). The present program would be useful for organ-based dosimetry and could also be used as a tool for teaching nuclear radiation physics and its interaction with the human body.


Assuntos
Radiometria , Software , Humanos , Radiometria/métodos , Imagens de Fantasmas , Método de Monte Carlo , Simulação por Computador
19.
Biomed Phys Eng Express ; 9(2)2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36689772

RESUMO

Achieving fast coincidence timing resolution (CTR) is an important issue in clinical time-of-flight positron emission tomography (TOF-PET) to improve the reconstructed image quality. One of the major factors affecting the CTR is the crystal surface treatment, which is often parameterized as surface roughness. However, previous studies on the crystal surface treatment optimization had two limitations of crystal-by-crystal variation and worse CTR over 200 ps. Here, we report the effects of the crystal surface treatment on the performance of a 20 mm long fast-LGSO crystal based TOF detector by tracking the same crystals in the sub-180 ps CTR regime. The light collection efficiency (LCE), energy resolution (ER) and CTR of the TOF detector were evaluated with six different crystal surface treatments of chemically polished (C.P), C.P half side roughened (1/2S) treatment, and then the C.P one side roughened (1S) treatment, mechanically polished (M.P) treatment, M.P 1/2S treatment, and M.P 1S treatment. The four lateral surfaces of each crystal were wrapped by using enhanced specular reflector film while the top surface was covered by using Teflon tape. The bottom surface of the crystal was optically coupled to a silicon photomultiplier. The timing and energy signals were extracted by using a custom-made high-frequency readout circuit, and then digitized by using a waveform digitizer. All the experimental conditions were same except the crystal surface treatment. Among the six different crystal surface treatments, the M.P 1S would be the optimal crystal surface treatment which balanced enhancements in the CTR (165 ± 3 ps) and ER (10.5 ± 0.5%). Unlike the M.P 1S, the C.P 1S did not enhance the CTR and ER. Hence, the C.P without roughening would be the second-best optimal crystal surface treatment which balanced the CTR (169 ± 3 ps) and ER (10.5 ± 0.5%).


Assuntos
Tomografia por Emissão de Pósitrons , Contagem de Cintilação , Tomografia por Emissão de Pósitrons/métodos , Fótons
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...